Problem How It Works Products Savings Why Us Models Request Free POC
EMS · ESG · AI · Smart Living Solutions

AI-Powered Energy Efficiency in Smart Parking

AI Smart Tube, intelligent lighting that senses vehicles and people, dims itself when nobody's there, and reports its own faults. Proven in Malaysian buildings. Zero CapEx option available.

SIRIM Approved IECEE CB Certified Works with Tuya ISO 9001:2015
90%
Max energy saving
3W
Avg consumption
60,000
Hours lifespan
Certified & Compliant

Certified to International Standards

Certification mark
Certification mark
Certification mark
Certification mark
Certification mark
Certification mark
Certification mark
Certification mark
Certification mark
Certification mark
The Problem

Challenges in Parking Lot Lighting

Most Malaysian car parks burn full-power lighting around the clock, whether a car passes or not. The costs show up in three ways.

Wasted Energy, Rising Bills

  • Lights run at 100% even when no car or person passes by
  • TNB AFA surcharges push the rate higher
  • The TNB bill keeps increasing, month after month

Rising, recurring electricity cost.

Maintenance That Never Ends

  • Regular bulb replacements on a rolling schedule
  • Technicians must be arranged and supervised
  • Extra cost added to building maintenance budgets

Ongoing, open-ended maintenance expense.

Complaints & Safety Gaps

  • Faulty lights switch off, and dark spots appear
  • Some lights stay on during the day, wasting money
  • Security guards patrol just to find failed tubes

Safety gaps and resident complaints.

Why Now

TNB AFA & Electricity Cost Trends

AFA, the Automatic Fuel Adjustment, is the fuel surcharge on your TNB bill. It is reviewed monthly, and the trend is up.

Source: myTNB published AFA rates (Aug 2025 – Jul 2026) and 3-month projection. Values in sen/kWj.

01

Media reports highlight rising electricity cost pressure, covered by The Edge, The Star and Berita Harian.

02

AFA for April 2026 was announced with a slightly lower rebate, meaning higher effective rates for buildings.

03

Energy-saving solutions are increasingly important for building operators who want to protect their budgets.

+2.59
Jun–Jul 2026
+8.33
Aug 2026 proj.
+8.94
Sep 2026 proj.
+8.04
Oct 2026 proj.
THE EDGE The Star Berita Harian myTNB

Malaysia is moving. The 13th Malaysia Plan (2026–2030) backs energy-efficient smart buildings.

ESG Smart Buildings & Cities AI & IoT Automation Carbon Reduction
The Better Way

Energy-Saving Solutions, Compared

Three ways buildings try to save on car park lighting, and why only one of them is guaranteed.

Traditional Sensor

Energy saving 30–50%

  • May not detect at longer distance
  • Lights may not turn on early enough
  • Sudden lighting feels uncomfortable
  • Safety risks in blind spots

Timer Solution

Energy saving 20–40%

  • Fixed schedule, no real-time detection
  • Energy still wasted in low-traffic periods
  • Manual switching needed in bad weather
  • Inflexible, often insufficient lighting
How It Works

How the Adaptive Dimming Works

A top view of a car park showing how tube groups brighten ahead of a moving car and return to 10% behind it.

Stepless Dimming, Microwave Sensing

Lights turn on when vehicle or human motion is detected and automatically dim when no motion is present. Dimming levels from 0–100% can be adjusted on the platform to match your building's requirements. Brightness ramps smoothly, never suddenly.

Localized Group Sensing

Tubes work as teams: when any tube in a group detects a vehicle or person, it triggers the whole group simultaneously, so lighting arrives before you do. Group logic is stored in each tube's built-in intelligent chip, keeping operation stable, safe and reliable even offline.

3W
power draw
10%
idle, no motion
Adaptive Brightness

Idle at 10%. Full light on motion. Back down when clear.

Before vehicle motion is detected, tubes hold a dim 10%. The moment the microwave sensor picks up an approaching car or pedestrian, brightness ramps to 100%, then eases back down after they leave. Every threshold is adjustable.

  • Reduces electricity costs without sacrificing safety
  • Proper lighting exactly when and where it's needed
  • All brightness values adjustable from the platform
The Hardware

The Hardware: Smart Tube & Gateway

A smart tube that senses and dims itself, and a gateway that connects every tube to the cloud.

AI Smart Tube · Bluetooth & Microwave T8

The light that thinks for itself

Wireless ConnectionLocal Bluetooth Offline AutomationRemote ManagementStatus Feedback
12W
dims 0–12W
150 lm/W
efficacy
10+ yrs
60,000 h life
5–8 m
detection range
Full specifications
ModelE5CL1800-865 G13 1200-2
Body1.2 m aluminum + polycarbonate (PC)/glass
Output1,800 lm · CRI 80
Color temperature3000K / 6500K
Detection angle120° – 150°
Recommended install height2 – 3 m
Bluetooth rangeUp to over 100 m in open area
Rated voltage100–240V ~ 50Hz
Ambient temperature-20°C to 45°C

IoT Gateway Pro

4G / Wi-Fi / Network cable, the bridge to the cloud

Wi-FiZigbeeBluetooth Remote ManagementStatus Feedback
400
devices: 200 Zigbee + 200 BT
35 m
indoor range
265 m
outdoor range
3
uplinks: 4G/Wi-Fi/LAN
Full specifications
Power input5V, 2A
Working current< 2A
Wireless protocolsWi-Fi, Zigbee, Bluetooth
Dimensions108 mm × 131.5 mm × 27.3 mm
Connectable sub-devices200 Zigbee + 200 Bluetooth
Stable control distance35 m indoors · 265 m outdoors

One gateway typically covers an entire parking floor. Final layout is confirmed during your free site survey.

The Software

Cloud Energy Usage Analytics

A cloud Energy Management System (EMS) plus a mobile app for monitoring consumption, savings and device status.

Total energy today
201,250 kWh
Energy saving rate
83%
Devices online
153
Carbon vs baseline
-8 tCO₂e
  • Real-time control & data collectionLive dashboards for consumption, comfort and environmental indices, with automated dimming schedules.
  • Excel / CSV / PDF report exportHand your JMB a ready-made savings report, no manual spreadsheets.
  • Carbon & ESG trackingCumulative carbon reduction reporting, aligned with Green Building Index goals. ISO 9001:2015 certified (SIRIM QAS).
  • Multi-building comparisonCompare consumption across buildings and locations from one screen.

Malaysia's only service provider with full software + mobile app lighting control, powered by Tuya.

On / Off & sensor mode Idle 10% ↔ Motion 100% Sensitivity: low / mid / high Hold duration control
See a live demo
Your Numbers

Annual Savings on the TNB Bill

Based on real measured data: conventional 18W tubes vs AI Smart Tubes averaging 3W. Adjust the sliders to match your building.

Your car park

Defaults reproduce our reference case: 1,000 tubes × 12 h × 360 days. AI Smart Tube average consumption 3W (10%–100% adaptive dimming).

Current annual usage77,760 kWh
Current annual costRM 41,524
With AI Smart Park: usage12,960 kWh
With AI Smart Park: costRM 6,921
Estimated saving: Year 1
RM 34,603
Year 1
RM 34,603
Year 3
RM 103,809
Year 5
RM 173,015
Trust & Compliance

Hardware Compliance & Certification

The hardware carries internationally recognized safety and quality certifications. Certificates and test reports are available on request.

Certificate of Conformity, compliant with Malaysian safety & electrical standards. Type-approved LED driver (IEC 60730).

The international "gold standard" for electrical safety testing, a direct pathway to CE, SIRIM, CCC, KC and RCM approvals.

60,000-hour lifespan test report from BACL, headquartered in Silicon Valley, USA, internationally accredited and recognized worldwide.

Photometric test reports, CNAS accredited, ILAC-MRA recognized, compliant with IEC/CIE standards accepted by global certification bodies.

Official Tuya identification authorization, hardware access to the Tuya cloud ecosystem for rapid, reliable smart control.

Compare Us

AI Smart Park vs Other Providers

A feature-by-feature comparison of AI Smart Park against a typical lighting provider.

FeatureAI Smart ParkTypical Provider
Certification✓ SIRIM approved, Malaysian safety & electrical standardsNo SIRIM certification mentioned
Proof of Concept✓ Free POC, real before/after readings verifiedUsually none; savings estimated upfront
Average power usage✓ 3W average thanks to AI dimmingHigher, from conventional sensor/LED systems
AI technology✓ Built-in AI chip, 10–100% smart dimming on movementTypically fixed brightness at lower watt
Energy Management System✓ Cloud + Local EMS, monitor, analyze, detect faults remotelyUsually no integrated EMS
Contract flexibility✓ Annually renewable, flexible for management / JMB / MC10-year fixed contract commonly required
Maintenance monitoring✓ Automatic fault reports through EMSUsually requires manual inspection
Estimated energy saving✓ Up to 65–90% with AI dimming technologyTypically lower, depending on sensor/timer setup
Cooperation Models

Cooperation Models: Buyout & Zero CapEx

Buyout Model

You own the system from day one

  • 5-year warranty, option to extend after year 5
  • 5 years of cloud platform usage included
  • Free energy-saving solution design & deployment
  • Free maintenance within 5 years
  • Free installation
Discuss Buyout
Most Popular with JMB / MC

Zero CapEx Model

Malaysia's first annually renewable contract, aligned to strata terms

We invest. You benefit. 100% funded by us.Profit sharing arranged after your free on-site survey
  • No upfront payment, start without any initial payment
  • No deposit, zero financial burden
  • Zero investment, free design, deployment, installation & maintenance
  • 5 years of cloud platform usage included
  • Annually renewable, no 10-year lock-in
Start with Zero CapEx

Both models begin with the same free Proof of Concept, measured on your own building.

Zero-Risk First Step

The Free Proof of Concept

Upon approval of the POC proposal, the schedule is finalized from your agreed start date. Four steps, zero cost.

★ 100% Free of Charge, no payment, ever, for the POC
01
Install an IoT meter

We measure your car park's existing energy usage, your real baseline, not an estimate.

02
Replace existing lights with AI Smart Tubes

A representative zone is upgraded to the adaptive dimming system.

03
Monitor readings on the mobile app

You watch the before/after consumption live, full transparency.

04
Results report presented to your committee

We prepare the POC results and present the findings during your meeting.

Real POC data: daily consumption
-45%
Before After AI Smart Tubes
Live Deployments

Reference Installations

Top Glove Tower
85%+ energy savedTop Glove Tower
Mines 2
87%+ energy savedMines 2
The Arcuz by EXSIM
79%+ energy savedThe Arcuz by EXSIM
Setia Sky Residences
81%+ energy savedSetia Sky Residences
Residensi Zahra 1
82%+ energy savedResidensi Zahra 1
The Stellar Condominium
76%+ energy savedThe Stellar Condominium
Top Glove Tower
85%+ energy savedTop Glove Tower
Mines 2
87%+ energy savedMines 2
The Arcuz by EXSIM
79%+ energy savedThe Arcuz by EXSIM
Setia Sky Residences
81%+ energy savedSetia Sky Residences
Residensi Zahra 1
82%+ energy savedResidensi Zahra 1
The Stellar Condominium
76%+ energy savedThe Stellar Condominium
Suria KLCC
Smart LightingSuria KLCCPremium Parking Zone
Sunway 163 Mall
Smart LightingSunway 163 MallParking Lot P1
Bandar Sunway Sunway Medical Centre
Smart LightingBandar Sunway Sunway Medical CentreTower D, B2 · 24/7
IJM-MEZZO
Smart CommunityIJM-MEZZOIoT-ready across the community
Suria KLCC
Smart LightingSuria KLCCPremium Parking Zone
Sunway 163 Mall
Smart LightingSunway 163 MallParking Lot P1
Bandar Sunway Sunway Medical Centre
Smart LightingBandar Sunway Sunway Medical CentreTower D, B2 · 24/7
IJM-MEZZO
Smart CommunityIJM-MEZZOIoT-ready across the community
Get Started

Request a Site Survey & Free POC

The proof of concept begins with a free site survey; results are measured on your building and presented to your committee.

We usually respond within one working day.